ABACUS 3.10.1 OFDFT Al1 practical examples

Read-only reference analysis: bash analyze.sh
Full recomputation: sbatch submit.slurm (CPU8173M template, not executed on unavailable dedicated node).
Reference calculations used abacus/3.10.1-p100 with device cpu, one MPI and one CPU thread. No GPU performance claim.
25 conditions: five kinetic functionals x three cutoffs; WT volume, optimizer, stopping-criterion and TF+weight controls. These form six teaching workflows, not25 independent properties.
The reference output contains actual energies, stress and optimization histories. Current build OFDFT charge export was zero; out_chg -1 disables invalid cube and automatic restart. No density grid or density-integral claim is provided.
See OUTPUT-SCOPE.txt and PROVENANCE.json. POTENTIAL choice, cutoff, criterion and volume convergence must be checked for the target material.